Leave Your Message
BTN210-250GC/E BLU Series A Quiet Note on a Gas Burner
News

BTN210-250GC/E BLU Series A Quiet Note on a Gas Burner

2025-08-22

2.webp

When a plant needs steady heat between 300 kW and 2 400 kW, the BTN210-250GC/E BLU series from Baite Burners is one of the few units that can be selected, installed and forgotten—almost. The range is offered in two frame sizes:
• BTN210~250 covers 300 kW – 2 400 kW
Both share the same basic architecture, so spares and know-how move easily from one site to another.
Modulation choices
The burner in two-stage operation mode: mechanical modulation (GC) or full electronic modulation (GE). Switching from one philosophy to the other is a matter of firmware and one additional servomotor; no new casting is required.
NOx
With staged air and fuel openings in the combustion head, NOx is kept below 80 mg/m³ without external flue gas recirculation. The figure is verified at 3 % O₂, dry basis, natural gas.
Service and layout
The hinged combustion head swings open without tools. Fan, valve train and control box are mounted on a sub-frame that can be slid forward once two screws are removed. Each functional group—air, gas, electrics—has its own quick connector, so a faulty component can be exchanged in the time usually spent diagnosing it.

Documentation

Installation instructions, wiring diagrams and CE declarations are shipped with every unit. All documents are available in English and Chinese.
Feel free to visit our official website for consultation, our offfice website: www.baiteburners.com.